Technical Data :

Parameter Details
Liquid Types Clean liquids or those containing small amounts of suspended solids or gas bubbles
Velocity Range Bi-directional to greater than 40 FPS
Flow Accuracy Up to 1% of reading depending upon transducer and flow rate
Temperature Accuracy Option A: 32 to 122°F; Absolute: 0.22°F; Difference: 0.09°F
Option B: 32 to 212ºF; Absolute: 0.45ºF, Difference: 0.18°F
Option C: -40 to 350ºF; Absolute: 1.1ºF, Difference: 0.45ºF
Option D: -4 to 85ºF; Absolute: 0.22ºF, Difference: 0.09ºF
Flow Sensitivity 0.001 FPS
Temperature Sensitivity Option A: 0.03ºF
Option B: 0.05ºF
Option C: 0.1ºF
Option D: 0.03°F
Repeatability 0.5% of reading
Compliance General Safety (all models): UL 61010-1, CSA C22.2 No. 61010-1; (power options A and D only) EN 61010-1
Hazardous Location (power supply options A and D only): Class I Division 2 Groups C, D; Class II and III, Division 2, Groups C, D, F, and G for US/CAN; ATEX II 2 G Ex nA II T4: UL 1604, CSA 22.2 No. 213, EN 60079-0 and EN 60079-15 CE: EN61326-1:2006 on meter systems with integral flow transducers, transducers constructed with twinaxial cable (all transducers with cables 100ft (30m) and shorter) or remote transducers with conduit
Display Two line LCD, LED backlit
Enclosure Type 4 (IP65) Construction: powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Configuration Via optional keypad or PC running ULTRALINK software
Engineering Units Flow Meter and Energy Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Energy Meter only: BTU, MBTU, MMBTU, Tons, kJ, kW, MW
Inputs/Outputs USB 2.0, RS485, 10/100 Base-T, 4-20mA,
0-1,000 Hz: open-collector (flow meter only), Two Alarm Outputs (flow meter only)

DOWNLOAD : DATASHEET Badger Meter Dynasonics TFX Ultra Clamp-on

SKU: 0677 Kategori: ,

Badger Meter Dynasonics TFX Ultra Clamp-on ultrasonic flowmeter

Badger Meter Dynasonics TFX Ultra Clamp-on ultrasonic flowmeter – TFX Ultra® ultrasonic flow and energy meters clamp onto the outside of pipes and do not contact the internal liquid. The technology has inherent advantages over alternate devices including:low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fluid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high flow rates.

TFX Ultra® is available in a variety of configurations that permit the user to select a meter with features suitable to meet particular application requirements.

The TFX Ultra® is available in two versions: a stand-alone flow meter, and an energy flow meter used in conjunction with dual clamp-on RTDs. The energy flow meter measures energy usage in BTU, MBTU, MMBTU, Tons, kJ, kW, MW and is ideal for retrofit, chilled water and other HVAC applications.

Technical Data :

Parameter Details
Liquid Types Clean liquids or those containing small amounts of suspended solids or gas bubbles
Velocity Range Bi-directional to greater than 40 FPS
Flow Accuracy Up to 1% of reading depending upon transducer and flow rate
Temperature Accuracy Option A: 32 to 122°F; Absolute: 0.22°F; Difference: 0.09°F
Option B: 32 to 212ºF; Absolute: 0.45ºF, Difference: 0.18°F
Option C: -40 to 350ºF; Absolute: 1.1ºF, Difference: 0.45ºF
Option D: -4 to 85ºF; Absolute: 0.22ºF, Difference: 0.09ºF
Flow Sensitivity 0.001 FPS
Temperature Sensitivity Option A: 0.03ºF
Option B: 0.05ºF
Option C: 0.1ºF
Option D: 0.03°F
Repeatability 0.5% of reading
Compliance General Safety (all models): UL 61010-1, CSA C22.2 No. 61010-1; (power options A and D only) EN 61010-1
Hazardous Location (power supply options A and D only): Class I Division 2 Groups C, D; Class II and III, Division 2, Groups C, D, F, and G for US/CAN; ATEX II 2 G Ex nA II T4: UL 1604, CSA 22.2 No. 213, EN 60079-0 and EN 60079-15 CE: EN61326-1:2006 on meter systems with integral flow transducers, transducers constructed with twinaxial cable (all transducers with cables 100ft (30m) and shorter) or remote transducers with conduit
Display Two line LCD, LED backlit
Enclosure Type 4 (IP65) Construction: powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting brackets
Configuration Via optional keypad or PC running ULTRALINK software
Engineering Units Flow Meter and Energy Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs, meters, cubic meters, liters, million liters, kg
Energy Meter only: BTU, MBTU, MMBTU, Tons, kJ, kW, MW
Inputs/Outputs USB 2.0, RS485, 10/100 Base-T, 4-20mA,
0-1,000 Hz: open-collector (flow meter only), Two Alarm Outputs (flow meter only)

DOWNLOAD : DATASHEET Badger Meter Dynasonics TFX Ultra Clamp-on

 

Rekomendasi Macam-macam Flow Meter :

Pelayanan Kalibrasi Flow Meter/ Water Meter :

Jasa Kalibrasi, Jasa Tera, Jasa Tera Ulang, Untuk Pengujian Flowmeter (Sertifikat Metrology) ;

  • Water Meter,
  • Oil Meter,
  • Gas Meter,
  • Listrik Meter &
  • Timbangan.

Informasi Pemesanan Badger Meter Dynasonics TFX Ultra Clamp-on Ultrasonic Flowmeter :

  • Phone:
    021 – 2913 – 5706
  • WA:
    +62812 – 8836 – 5600
  • Email:
    p722indonesia@gmail.com
  • Address:
    Mega Glodok Kemayoran – Mall MGK Lantai UG – Blok D6 No. 3
  • Opening Hours:
    Monday – Friday ; 09:00 am – 17:00 pm
    Saturday – Sunday ; Closed

By. PT Putra Siduasaudara Indonesia



Exclusive products

Special category of products
X
Need Help? Whatsapp Me..