CAMERON MC-II NUFLO Flow Analyzer
CAMERON MC-II NUFLO Flow Analyzer
Features :
- Imbedded units of measure conversion factors simplifies calibration to popular units of measure
- Calibration data is retained even without battery; totals can be saved by pressing the ENTER/STOP button on the keypad
- Total reset: may be reset to zero from front panel
- Calibration: Settings made from front panel
- Security: Password security may be activated as a requirement to reset the total or change the calibration
- Swivel and tilting head for optimal viewing
- Weatherproof electrical connector and treaded union style direct mount connector for efficient installation
Specifications Cameron MC-II Nuflo Flow Analyzer :
- Size (W × H × L): 7.3 in × 8.3 in × 3.4 in [185 mm × 211 mm × 89 mm]
- Weight: 6 lbm including shipping container
- Power supply: One 3.6 volt lithium battery (restricted air transport regulations apply)
- Temperature range: −40 to 140 degF [−40 to 60 degC]
- Totalizer and flow rate display: six digits, bold, 6-in tall
- Divisor or calibration factor range: 0.001 to 999,999
- Standard units: bbl and bbl/d (other units of measure selectable during commissioning)
- Accuracy: ±1 count (totalizer)
- Input frequency: 0–3,500 Hz
- Input amplitude: 30–3,000 mV peak to peak.