SHM INSERTION ELECTROMAGNETIC FLOW METERS
SHM Insertion Electromagnetic Flow Meters body are made from SS304 and the electrode are made from SS316L. The device are combining both transducer and transverter. Which is used to measure the volume and flow rate of various conducting liquid inside the pipeline.
Applications :
A variety of liquid can be accomodated : ultra-pure liquids, potable water, chemicals, raw sewage, reclaimed water, cooling water, river water, plant effluent, petrol, etc. Widely used in metallurgy, electric power plant, irrigation, city water company, energy monitor fields.
Features SHM Insertion Electromagnetic Flow Meters :
- Power supply : 24V or 220V
- Applicable for pipe diameter 200-2000mm
- Flow Rate : 1-10 m/s
- Accuracy : +/-5%
- Conductivity of measured medium : 5ms/cm
- Pressure : 1.6 Mpa.
- Temperature : 60°C
- Output signal : DC 0-10mA, 4-20mA
- Warranty 2 years ( Full service and spare part).
Specifications :
Model | Electromagnetic Flow Meter (Insertion) |
Size | DN200-450 / 500-950 / 1000-1500 |
Brand | SHM Meters |
Material | Head Epoxy Coated Aluminium |
Body SS304 | |
Temperature | Integrated 0~100°C / Separated 0~120°C |
Pressure | 16 Bar |
Power Supply | 220V AC / 24V DC |
Output | Pulse, 4-20mA HART, RS485 (Modbus) |
Protection Grade | IP 65 Head / IP 68 Body |
Connection | Insertion |
Accuracy | +/- 0.5% |
Measurement Range | 0.1-15 m/s |
Repeatibility | – |
Explosion Proof | Exd II BT4 |
Application | Conductive Water,
Not Applicable for RO, Denim, Filtered Water. |
Electrode Material | SS316 / Tungsten Carbide/ Hastelloy B/ Hastelloy C/ Titanium/ Tantalum/ Platinum Iridium. |
Lining Material | Polytetrafluoroethylene (PTFE)/ PFA/ F46/ Neoprene/ Polyurethane. |
ISO 9001 & ISO 4064 | |
Warranty 2 Years (Full Service & Spare Parts) |
Technical Data SHM Insertion Electromagnetic Flow Meters DN10~DN100 :
Size (mm) |
Nominal Pressure (Mpa) |
Flow Rate (m3/h) | Dimension (mm) |
Weight Integrated (Kg) |
||||
Min. Flow 0.5 m/s | Max. Flow 15 m/s | L | B | H
(Separated) |
H
(Integrated) |
|||
DN10 | 1.6 | 0.14 | 4.24 | 200 | 90 | 190 | 265 | 9.5 |
DN15 | 1.6 | 0.31 | 9.54 | 200 | 95 | 190 | 265 | 10 |
DN20 | 1.6 | 0.56 | 16.96 | 200 | 105 | 200 | 275 | 12 |
DN25 | 1.6 | 0.88 | 26.50 | 200 | 110 | 210 | 285 | 14 |
DN32 | 1.6 | 1.44 | 43.42 | 200 | 110 | 220 | 310 | 15 |
DN40 | 1.6 | 2.26 | 67.85 | 200 | 150 | 230 | 320 | 16 |
DN50 | 1.6 | 3.53 | 106.02 | 200 | 165 | 245 | 335 | 17 |
DN65 | 1.6 | 5.97 | 179.18 | 200 | 185 | 265 | 355 | 25 |
DN80 | 1.6 | 9.04 | 271.43 | 200 | 200 | 280 | 370 | 29 |
DN100 | 1.6 | 14.13 | 424.11 | 250 | 235 | 300 | 390 | 31 |
Technical Data SHM Insertion Electromagnetic Flow Meters DN125~DN600 :
Size (mm) |
Nominal Pressure (Mpa) |
Flow Rate (m3/h) | Dimension (mm) |
Weight Integrated (Kg) |
||||
Min. Flow 0.5 m/s | Max. Flow 15 m/s | L | B | H
(Separated) |
H
(Integrated) |
|||
DN125 | 1.6 | 22.08 | 662.67 | 250 | 330 | 420 | ||
DN150 | 1.6 | 31.08 | 954.25 | 300 | 300 | 360 | 450 | 41 |
DN200 | 1.6 | 56.54 | 1696.46 | 350 | 340 | 420 | 505 | 45 |
DN250 | 1.6 | 88.35 | 2650.71 | 400 | 405 | 480 | 560 | 50 |
DN300 | 1.6 | 127.23 | 3817.03 | 500 | 460 | 530 | 610 | 60 |
DN350 | 1.6 | 173.18 | 5195.40 | 500 | 520 | 590 | 670 | 145 |
DN400 | 1.6 | 226.19 | 6785.84 | 600 | 580 | 645 | 725 | 180 |
DN450 | 1.6 | 286.27 | 8588.32 | 600 | 640 | 695 | 775 | 215 |
DN500 | 1.6 | 353.42 | 10602.87 | 600 | 715 | 750 | 830 | 245 |
DN600 | 1.6 | 508.93 | 15268.14 | 600 | 840 | 855 | 940 | 335 |
Technical Data SHM Insertion Electromagnetic Flow Meters DN700~DN3000 :
Size (mm) |
Nominal Pressure (Mpa) |
Flow Rate (m3/h) | Dimension (mm) |
Weight Integrated (Kg) |
||||
Min. Flow 0.5 m/s | Max. Flow 15 m/s | L | B | H
(Separated) |
H
(Integrated) |
|||
DN700 | 1.6 | 692.72 | 20781.63 | 700 | 910 | 970 | 1055 | 435 |
DN800 | 1.6 | 904.77 | 27143.36 | 800 | 1025 | 1090 | 1170 | 545 |
DN900 | 1.6 | 1145.11 | 34353.31 | 900 | 1125 | 1190 | 1270 | 655 |
DN1000 | 1.6 | 1413.71 | 42411.50 | 1000 | 1255 | 1290 | 1380 | 810 |
DN1200 | 1.0 | 2035.75 | 61072.56 | 1200 | 1455 | 1530 | 1610 | 875 |
DN1400 | 1.0 | 2770.88 | 83126.54 | 1400 | 1675 | 1740 | 1820 | 1235 |
DN1600 | 1.0 | 3617.11 | 108573.44 | 1600 | 1915 | 1950 | 2050 | 1555 |
DN1800 | 0.6 | 4580.44 | 137413.26 | 1800 | 2045 | 2170 | 2250 | 2085 |
DN2000 | 0.6 | 5654.88 | 169646 | 2000 | 2265 | 2380 | 2460 | 2610 |
DN2200 | 0.6 | 6842 | 205217 | |||||
DN2400 | 0.6 | 8143 | 244290 | |||||
DN2600 | 0.6 | 9556 | 206701 | |||||
DN2800 | 0.6 | 11083 | 332506 | |||||
DN3000 | 0.6 | 12723 | 381703 |
PT Putra Siduasaudara Indonesia
Rekomendasi Macam-macam Flow Meter :
- SHM Gas Meter Vortex
- SHM Gas Meter Turbine Digital
- Tokico Flow Meter
- Nitto Seiko Flow Meter
- SHM Gas Meter Vortex-TP
- Water Meter MulFunction Sewage SHM (Limbah)
- Oval Gear Flowmeter SHM
- Water Meter Woltman SHM
- Liquid Controls Flow Meter
- Avery Hardoll Flow Meter
- Water Meter Multi-Jet Brass SHM
- SHM Vane Flange Cast Iron
- Micro Oil Flow Meter SHM
- Flow Meter Scraper SHM
- Fill-Rite Flow Meter
- Flow Meter Ultrasonic SHM
- SHM Multi-Jet ABS
- Water Meter Stainless Steel SHM
- B&R Water Meter
- SHM Roots Flow Meter
- Macnaught Flow Meter
- OGM Oval Gear Flow Meter
- Oval Flow Meter
- SHM Flow Meter
- Onda Water Meter
- Flomec Flow Meter
- Aquametro Flow Meter
- Powogaz Water Meter
- Dll.
Pelayanan Kalibrasi Flow Meter/ Water Meter :
Jasa Kalibrasi, Jasa Tera, Jasa Tera Ulang, Untuk Pengujian Flowmeter (Sertifikat Metrology) ;
- Water Meter,
- Oil Meter,
- Gas Meter,
- Listrik Meter &
- Timbangan.